U-CAT SA603

Thermal latent base generator. DBU formate active at about 135 °C.

CAS RN® 51301-55-4
Component DBU/formate salt
Base generating temperature Approx. 135℃

Physical characteristics / Packing

Appearance White~Pale Yellow Solid
Packing 12kgCAN
Sample Free Sample:100g


Q&A

What kind of application can it be applied to?
It is used as urethane catalysts and epoxy curing accelerators.
Is it a thermal latent catalyst?
Yes, DBU dissociates at about 135 °C and exhibits catalytic activity.
Can it be used as a tin-free catalyst in urethane catalysts?
Yes.
Are there any handling precautions?
As it is deliquescent, please be careful about moisture when storing and handling.